High-Rise Cleaning Drone Tutorials

This comprehensive tutorial series focuses on the EAUAV C80/C80P high-rise cleaning drone (capable of reaching heights up to 120 meters), guiding you step-by-step through setup, operation, and maintenance. From basic controls, software integration, and mission planning to advanced cleaning techniques, troubleshooting, and maximizing efficiency, we ensure safe, professional, and transformative outcomes for your high-altitude cleaning operations.

EP12: Project Delivery – Quality Inspection & Data Reporting

After every job, do a short debrief.

  1. Delivery & result check

When the facade dries, the observer checks from bottom to top: missed areas, streaking, runoff marks, dirty water residue. If residue remains, check whether foam dwell time was too short, or the final rinse wasn’t thorough enough.

Take “Before/After” photos from the same angles—at least 3 sets per side: wide / mid / detail.

Confirm acceptance criteria with the client/property: cleanliness level, water-spot requirement, any rewash needed.

  1. Data logging

Record total water used, number of batteries consumed, and total cleaned area.

Suggested job log fields:

  • Project: location / building height / facade material / contamination type / weather & wind
  • Parameters: nozzle angle, pressure level, flow rate, standoff distance, flight speed, mode (manual / AB / auto area)
  • Output: total area (m²), total duration, total flights, average efficiency (m²/h), water use / chemical use
  • Battery: packs used, cycle count / depth of discharge, any voltage or temperature anomalies
  1. Safety review Any near-misses: almost hit facade, hose snag, weak signal, strong wind swing, pedestrians entering the zone—write down the cause clearly. List today’s risks and improvements: tighter perimeter, adjust takeoff point, add one more ground crew, shorten operating radius.
  2. Equipment status loop If you see abnormal warnings, export logs and capture screenshots immediately for remote diagnosis. Track consumables: props, nozzles, filters, hose wear points—record “replace needed / estimated time.” Pump: flush and drain, clean filter, log hours and follow maintenance cycle (first 50h oil change, then every 100h).
  3. Send a Daily Job Brief to the client Include: before/after photos + area/water/time + safety measures + next-step recommendation. Ask for one short testimonial for case studies and social media—and schedule the next maintenance cycle.